Overview
When using Xinet version 2023.6.1 on RHEL 7.9, you may encounter issues with metadata not being included in data exports. This is a known defect in this version, resolved in later updates. If upgrading is not feasible, you can attempt to synchronize metadata with the database using the syncvoltodb
command as a potential workaround.
Information
If you are experiencing issues with metadata export in Xinet version 2023.6.1 on RHEL 7.9, you can try the following steps to synchronize metadata with the database:
- Open a terminal on your server.
- Run the following command to force a sync on the affected path:
Replacesyncvoltodb -delnorm -noarch /path/to/file/or/directory
/path/to/file/or/directory
with the actual path you need to synchronize. - This command will ensure that all metadata from the specified path is properly synchronized with the database.
This procedure is documented in the article "Synchronizing a Single Path on the Volume with Xinet Database." Running this command may help resolve potential indexing discrepancies.
Frequently Asked Questions
- What is the
syncvoltodb
command used for? - The
syncvoltodb
command is used to synchronize metadata from a specified path with the Xinet database, which can help resolve potential indexing discrepancies. - Why can't I export metadata in Xinet version 2023.6.1?
- Metadata export issues in Xinet version 2023.6.1 on RHEL 7.9 are due to a known defect that has been fixed in later versions. If upgrading is not feasible, synchronizing metadata with the database using the
syncvoltodb
command may help. - Is there a patch available for Xinet version 2023.6.1?
- No, engineering will not release patches or backports for older versions, as they focus on supporting the most recent releases. Upgrading to a newer version is recommended for long-term stability.
Priyanka Bhotika
Comments